BOILPLEX AT Hardness Control

Sewage Chemicals Treatment-40

BOILPLEX AT Hardness Control

Phosphate and polymer Based Boiler treatment chemicals

In addition to controlling the alkali content, scale and sediment, Boilplex ATprotects the condensate system (Steam superheater) from corrosion caused by low pH. Boilplex AT control sludge and sediment deposition by adsorption on sludge boiler surfaces, Particles are soft, do not stick together

Key details

Generic name Phosphate and polymer Based Boiler treatment chemicals
Active matter (%) 72-75
Standard packing 25.00 Ltr.
Available pack sizes Phosphate and synthetic polymer Based Boiler water treatment chemicals to control sludge for low and medium pressure boilers which results in the clean boiler water. USES of RXSOL BOILPLEX AT Hardness Control provide tolerance of feedwater quality fluctuations. The ready stock of BOILPLEX AT Hardness Control is in 25, 50 Ltr packing.
Supply locations Phosphate and synthetic polymer Based Boiler water treatment chemicals to control sludge for low and medium pressure boilers RXSOL BOILPLEX AT Hardness Control manufacturer ans supplier in Mumbai, Gandhidham Surat Gujrat, Chennai, Ennore, Visakhapatnam VIZAG Andhra Pradesh, Kolkata, Haldia, Paradip, Fujairah, Sharjah, Ajman, Abudhabi, Muscat Oman, Canada BE, Nairobi Mombasa, Kenya, Jinja Kampala, Uganda

Need this product at your port or plant?

Enquire Now
Application

To be most effective to prevent corrosion and scaling using drug Boilplex AT the drug should be constantly adding to the boiler system with a dosing devices BWT Dosing System.  Less preferable to use gravitational dosing device, because  preparation can evaporate when the water returns into the tank cascade.

Using Procedure

Regularly enter solutions drugs Boilplex AT with a dosing device BWT Dosing System in feedwater recirculation outlet below which returns cascading water in the tank.  If there is no recirculation of feedwater, the drug should be submitted in suction tube feeding pump.  When using gravity dispenser the drug should be fed to the point of feed water tank or in cascade.  Drug supply line should be higher than normal water level (about 1 meter) and as close as possible to the fence of water nutrient pump. Boilplex AT to be dissolved in distilled water or condensate in the dispensing tank and gradually continuously fed for 24 hours, keeping the system demand.  The daily dosage is depend on the volume of the system, the condensate quality and purity, as well as the quality and quantity of the feed water system.  For standard operating systems the dosage Boilplex AT is about 1 liter a day.

Very large systems or in non-standard conditions will have a greater need for preparation. Many factors can affect the initial dose of the drug.  The two most important factors - quality feedwater and the boiler. The recommended initial dose of 2.5 to 5 liters per tonne of water system.  After the initial filling of the product during operation of the system on a daily basis should perform a test to adjust the dosage.  Low quality feedwater demands increase quantities of preparation, as well as leaching of the polluted water from the boiler of the boiler due to the settling of particles on bottom of the boiler during system shutdown.  This in turn entails the need for additional purging and increase the amount of drug. 

The main objective of the program - to prevent fouling.  The most effective way to fight c deposits is to use distilled water feed.  Boilplex AT created for removing water hardness instability.

 Blowdown

Purge procedure is necessary for the effectiveness of any treatment program and boiler watershall be in accordance recommendations manufacturer's instructions.  Purging is required to remove the precipitate dissolved and suspended solids.  Normal regular purging with sufficient neutral of conductivity 700 μmho.  A higher rate of conductivity (above 700 μmho) frequency blowdown should be increased.  Additionally, it is recommended to wash weekly collector or separator pair (if any) to reduce the accumulation of sludge.

Technical Specifications

 

Appearance

: Clear liquid

Specific gravity at 25 º C (77 º F)

: 1.056

Fire

: off

Freezing temperature

: -6.6 º C (20 º F)

pH

: 13.4

Stability after freeze / that

: yes

Remarks

<p style="text-align: justify;">
<span style="color: rgb(85, 85, 85); font-family: Tahoma, Verdana, Arial, Helvetica, sans-serif;">Did you know, how to keep BOILER water CLEAR and Sludge free?</span><br />
<br style="color: rgb(85, 85, 85); font-family: Tahoma, Verdana, Arial, Helvetica, sans-serif;" />
<span style="color: rgb(85, 85, 85); font-family: Tahoma, Verdana, Arial, Helvetica, sans-serif;">RXSOL BOILPLEX AT Phosphate and synthetic polymer Based Boiler water treatment chemicals to control sludge for low and medium pressure Boilers which results in the clean boiler water. USES of RXSOL BOILPLEX AT Hardness Control provide tolerance of feedwater quality fluctuations.</span><br style="color: rgb(85, 85, 85); font-family: Tahoma, Verdana, Arial, Helvetica, sans-serif;" />
<br style="color: rgb(85, 85, 85); font-family: Tahoma, Verdana, Arial, Helvetica, sans-serif;" />
<span style="margin: 0px; padding: 0px; color: rgb(58, 58, 58); font-family: Raleway, sans-serif; font-size: 14px; text-align: justify;">Chemically one part of The polymers used in BOILPLEX AT  keeping the sludge particles soft by increasing property of nonadherent which also resulting smooth blowdown during boiler cleaning and maintenance operation.</span><br />
<br />
<br />
<span style="margin: 0px; padding: 0px; color: rgb(58, 58, 58); font-family: Raleway, sans-serif; font-size: 14px; text-align: justify;">While Other part of Phosphate which is used in BOILPLEX AT serve as deposit control agents by </span><span style="margin: 0px; padding: 0px; color: rgb(58, 58, 58); font-family: Raleway, sans-serif; font-size: 14px; text-align: justify;">Iron dispersancy, main cause of sequestering deposits.</span><br />
<br />
<span style="margin: 0px; padding: 0px; color: rgb(58, 58, 58); font-family: Raleway, sans-serif; font-size: 14px; text-align: justify;">USES</span><span style="color: rgb(85, 85, 85); font-family: Tahoma, Verdana, Arial, Helvetica, sans-serif;"> of </span><span style="margin: 0px; padding: 0px; color: rgb(58, 58, 58); font-family: Raleway, sans-serif; font-size: 14px; text-align: justify;">RXSOL BOILPLEX AT boiler water treatment, can help BOILER</span><span style="color: rgb(85, 85, 85); font-family: Tahoma, Verdana, Arial, Helvetica, sans-serif;"> WATER CLEAN and CLEAR.</span></p>

Note

Testing:

Dosage and frequency Boilplex AT controlled blowdown simple tests on the quality of the boiler water.Tests include checking parameters such as hydrate alkalinity, conductivity, phosphates, stiffness feedwater and condensate pH.  For more information about the testing procedure, refer to Table control the amount and dosage Boilplex AT  Control and Dosage Chart or contact representative of Rx Marine International.

CHARACTERISTICS :
 

  • Has dispersant properties.
  • Converts crystals.
  • Comprehensive protection.
  • Air conditioning sludge.
  • Multi-tool.
  • Prevents scale.
  • Easy to use and testing.

BENEFITS

  • Do not allow the particles to stick together.
  • Do not allow the build-up of scale on pipes.
  • Provides efficient heat transfer.
  • Soft sludge" can be easily removed by blowing.
  • Redundant components ensure protection.
  • Boiler Cleaner.
  • Increases in operation.
  • Reduces the need for acid peels.
  • Saves maintenance costs Kotel.
  • Control of corrosion caused due to low.
  • pH levels in the condensate system.
  • Controls alkalinity.
  • Controls the formation of a new scale.
  • Convenient for operator.

Related products

From our blog

Need BOILPLEX AT Hardness Control for your operation?

Our team helps with product selection, dosage, safety data and delivery worldwide.

Request a Quote