Leak Tester CO2 Cylinders
Carbon Dioxide Leak detection test Kit
Leak Testing reagent for CO2 Cylinders leak test. On Leak detection deep pink colour of reagent changes into colourless.
Key details
| Generic name | Carbon Dioxide Leak detection test Kit |
|---|---|
| Standard packing | 1.00 Bottle |
| Available pack sizes | 50ml, 100 ml, 500 ml |
| Supply locations | Leak Tester CO2 Cylinders test kit manufacturer and supplier in Mumbai, Kandla, Fujairah, Sharjah, Ajman, Abudhabi, Dubai, UAE Middle East, Muscat, Barka Sohar Oman, Yemen, Nairobi, Kenya Africa, Canada, Kolkata, Surat Gandhidham Gujrat, Chennai, Visakhapatnam |
Need this product at your port or plant?
Enquire Now<div id="cke_pastebin">
Leak Testing of CO2 Cylinders Testing Method ::: </div>
<div id="cke_pastebin">
</div>
<div>
Required Materials :::</div>
<div id="cke_pastebin">
1) Transparent Polythene bags of a <span style="font-size:14px;">suitable size</span> to fit over the head of the cylinder. For eg. for 5.5" diameter cylinder the bag size is approximately:- 9" open width x 12" length. And For a 4" diameter cylinder, bag size is approximately 6.5" open width x 12" length. And For a 3.5" diameter cylinder, bag size is approximately 5.75" open width x 12" length.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
2) Elastic bands of a suitable size to tighten Polythene Bag on Cylinder Head to Make sure there are no air gaps in the seal.</div>
<div>
</div>
<div id="cke_pastebin">
3) A measuring cylinder, 25 ml capacity.</div>
<div id="cke_pastebin" style="text-align: justify;">
<br />
4) Test Solution - RXSOL-66-6201-500, The solution shall be stored in a cool place in dark coloured glass bottles with a tight fitting screw cap. If so stored the shelf life is approximately 12 MONTHS.</div>
<div id="cke_pastebin" style="text-align: justify;">
<div id="cke_pastebin">
Testing Method :<br />
First of all clean valve and shoulder of the cylinder to make sure connecting portion are free from dust and other contaminants by carefully wiping using a clean, dry cloth. Remove the dust cap to clean the valve then replace the cap loosely.<br />
</div>
<div id="cke_pastebin">
Then Lay down the cylinder under test on its side in a rack, such that the valve end is protruding.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Testing procedure begin with by Using measuring cylinder to take 25 ml of the RXSOL-66-6201-500 test solution into a polythene bag, Pl. be note A control quantities of sample is necessary, which is made by introducing 25 ml of test solution. Then follow these step :::</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
1) Attach the open end of the bag over the valve head and attach it to the cylinder body. Tighten Polythene bags using one or more elastic bands. Make sure there are no air gaps in the seal. And also try to hang polythene bag minimum 20 cm off the valve end of the cylinder with the test solution in one corner.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
2) Maintain the test for a period of not less than 4 hours and not more than 4.5 hours.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Final Observations</div>
<div id="cke_pastebin">
1) The presence of a leak of carbon dioxide from the cylinder will cause the pink colour to the test solution to be lost and the test solution will become water white.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
2) If no colour change is observed there is no leak of gas from cylinder. </div>
</div>
Related products
Need Leak Tester CO2 Cylinders for your operation?
Our team helps with product selection, dosage, safety data and delivery worldwide.
Request a Quote