Boiler Water Sludge Conditioner

Sewage Chemicals Treatment-40

Boiler Water Sludge Conditioner

Sludge Conditioner

Product to be used in situations where the boiler water is contaminated with oil. This high performance product is applicable to both medium and low-pressure steam boilers in order to prevent sludge deposits.

Key details

Generic name Sludge Conditioner
Active matter (%) 63-72
Standard packing 25.00 Ltr.
Available pack sizes Sludge conditioner for Boiler water packed in 20, 25, 50, 50, 210 Ltrs packing. And we are keeping ready stock at Mumbai, Gandhidham, Surat, Visakahapatnam, Ennore- Chennai, Kolkata - Haldia, Paradip, Fujairah, Dubai, Sharjah, Abu Dhabi.
Supply locations Boiler Water Sludge Conditoner manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Surat, Gujrat, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Boiler Water Sludge Conditoner at a competitive price from us. We have ready stock of Boiler Water Sludge Conditoner in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Need this product at your port or plant?

Enquire Now
Application

Note that BOILER SLUDGE CONDITIONER can be applied as it is or dissolved with other boiler treatment products. 

SAFETY AND HANDLING HANDLING Handle with care. Store in a dry, cool and well ventilated environment.

Using Procedure

A. Dosing Procedure Regularly, a volume of 100 ml of the BOILER SLUDGE CONDITIONER should be applied for every ton of water capacity, where oil contamination exists. How ever, in systems where severe oil contamination exists, off-line cleaning is required before the product can be applied. There after, the application should be repeated daily, for a period of two weeks, until oil removal is complete.

B. Feeding Procedure Feed directly to the boiler by using a bypass pot feeder or a suitable chemical injection pump. For low-pressure boilers the solution may be applied to the hot well or the condensate return tank.

Technical Specifications

This is a white high molecular weight solution. It is hydrophilic and of low causticity.
Appearance / Color : White, viscous liquid 

pH : 8
Odor : Odorless 

Remarks

<p style="text-align: justify;">
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Our others valauable Products : <br />
BOILER TREAT ONE SHOT</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Combined Boiler Water Conditioner</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">A one-product treatment for all auxiliary boilers including waste heat, and exhaust gas boilers. it prevents scale formation, inhibits corrosion and conditions sludge.</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">HARDNESS CONTROL</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Boiler Water Conditioner</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Added to the boiler water to maintain optimum phosphate level, which prevents calcium and magnesium hardness salts formation. The precipitate can be removed by blow-down.</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">ALKALINITY CONTROL</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Boiler Water Conditioner </span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Added to the boiler water to maintain optimum alkalinity level to prevent corrosion. Due to this, Ca and Mg hardness salts cannot form and the precipitate is removed by blow-down.</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">HYDRAZIDE</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Oxygen Scavenger </span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Used for rapid removal of oxygen in boiler feed water and condensate systems, which prevents corrosion. It is the alternative for hazardous and potentially carcinogenic products.</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">BOILER TREAT COMBI</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Organic Boiler Water Treatment </span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Special blended low molecular weight compounds that elevate boiler water pH to levels, which reduce corrosion. It also prevents under deposit corrosion caused by excess alkalinity.</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">LIQUID COAGULANT</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Oil and Sludge Conditioner </span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Used to prevent formation of adherent deposits and sticky sludge in boilers,which are then removed by normal blow-down. It can also be used in the event of an oil contamination.</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">CONDENSATE CONTROL</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Steam and Condensate Conditioner </span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Injected into the condensate pump to prevent corrosion in steam and condensate lines.It’s also used to protect idle boilers from corrosion. It neutralizes acidic conditions in condensate systems and volatilizes with steam.</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">COOL WATER TREAT NCLT</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Corrosion and Scale Inhibitor </span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Provides an effective anodic inhibitor treatment and protects ferrous and non-ferrous metals. It deposits a microscopic protective film on surfaces and has built-in pH buffering compounds. It controls formation of hard scale deposits.</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">EVEPORATOR TREAT</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Prevention of scale in Evaporators</span><br style="font-family: Arial, Helvetica, sans-serif;" />
<span style="font-family: Arial, Helvetica, sans-serif; font-size: small;">Used in both high and low pressure evaporators to prevent foaming, carry-over and scale formation. It’s safe to use where distillate is used for drinking purposes. It prevents scale formation and avoids the need for acid descaling.</span></p>

Note

Environmentally safe, non-toxic product

Highly specialized combined polymer technology

Organic corrosion control

Stops excessive caustic build-up

Avoid hardness scale and sludge deposits

Operates with low dissolved solid levels

Quick, simple and accurate testing 

Drives to the coagulation of the oil droplets and their removal by blow-down. May be combined with other boiler water treatment products. Efficiently prevents the deposition of sludge. Easy to apply and use. 

Related products

From our blog

Need Boiler Water Sludge Conditioner for your operation?

Our team helps with product selection, dosage, safety data and delivery worldwide.

Request a Quote