Chloride Test Kit

Test Kit For Water-62

Chloride Test Kit

Test kit for water treatment

Determination of Chloride ppm value

Key details

Generic name Test kit for water treatment
Active matter (%) 100%
Standard packing 1.00 Full SET
Available pack sizes Ready stock at Kolkata, Mumbai, Chennai - Ennore, Visakhapatnam, Kandla, Fujairah - Dubai
Supply locations Calculations The constant weight of the crucible = a g The constant weight of the crucible AgCl = b g Weight of AgCl = (b – a ) g Now AgCl ( 143.34 ) = Cl- ( 35.46 ) = NaCl ( 58.46 ) Here Simple Calculation is : 143.34 g of AgCl = 35.46 g of chloride (b–a)gofAgCl = 35.46/143.34x(b–a)g of chloride or 25 ml of the given solution contains = 35.46/143.34 ( b – a ) g of chloride Amount of Cl- ion present in one liter of the solution = 35.46/143.34 x( b – a )x1000/25 = 35.46 x( b – a ) x40 / 143.34 g Similarly, the strength of NaCl solution in g/liter of the solution = 58.46 x( b – a ) x 40 / 143.34 g

Need this product at your port or plant?

Enquire Now
Application


PROCEDURE for test ( STEP WISE ):

  1. Measure 15 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
  2. Add 1-2 drops of  RXSOL TK1 and mix with the stirring rod , If  sample turns red / PINK then follows 3rd step otherwise if sample remains colourless proceed to step 4.
  3. Add RXSOL TKdrop by drop , mixing with the stirring rod until colour just disappears.
  4. Add 3 drops of RXSOL TK3 and mix with stirring rod , the sample will turn YELLOW.
  5. AddRXSOL TK4 carefully by counting drop by drop and mixing throughly until a light reddish / pink / brown colour develop.
Using Procedure


RESULT  : Each DROPS is equivalent to 8 PPM of CHLORIDES .
Small amount of sample is collected in a test tube and an indicator reagent is added to the sample. Use the dropper bottle, the titrant, until the color changes. To calculate the concentration just multiply the number of drops required by the titrant by a simple factor given in the test kit manual.

VIDEO HELP : https://www.youtube.com/watch?v=p_IgKoO49iE

Technical Specifications

<p>
OFFER :::---<br />
Do not forget to ask JUMBO PACK OFFER  (  <strong><span style="color:#00f;">TK</span></strong> - extra pack )<br />
<br />
BUY 2 - GET 2   <em><span style="font-size:18px;">FREE </span></em><span style="font-size:14px;"><strong><span style="color: rgb(0, 0, 255);">TK</span></strong></span> extra pack</p>

Remarks

<p>
<br style="text-align: justify;" />
<strong style="text-align: justify;"><u>REAGENT & APPARATUS</u></strong><span style="text-align: justify;">:</span><br style="text-align: justify;" />
<strong style="text-align: justify;"><span style="font-size: 16px;">Reagent</span></strong><span style="text-align: justify;">:  RXSOL </span><strong style="text-align: justify;"><span style="color: rgb(0, 0, 255);">TK</span></strong><span style="text-align: justify;"> 1 , </span><span style="text-align: justify; color: rgb(0, 0, 255);"><strong>TK</strong></span><span style="text-align: justify;"> 2 , </span><span style="text-align: justify; color: rgb(0, 0, 255);"><strong>TK</strong></span><span style="text-align: justify;"> 3 , </span><span style="text-align: justify; color: rgb(0, 0, 255);"><strong>TK</strong></span><span style="text-align: justify;">4 .</span><span style="text-align: justify; font-size: 16px;"> <strong>Apparatus </strong></span><span style="text-align: justify;">: TEST TUBE , Titrator or DROPPER.<br />
<br />
VIDEO Help :  </span><a href="https://www.youtube.com/watch?v=p_IgKoO49iE">https://www.youtube.com/wa…;

Note

 

TK4 Drops

Chloride value in

PPM

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

8

2

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

16

3

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

24

4

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

32

5

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

40

6

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

48

7

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

56

8

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

64

9

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

72

10

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

80

11

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

88

12

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

96

13

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

104

14

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

112

15

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

120

16

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

128

20

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

160

24

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

192

26

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

208

28

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

224

30

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

240

32

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

256

34

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

272

36

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

288

38

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

304

40

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

320

42

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

336

44

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

352

46

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

368

48

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

384

50

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

400

55

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

440

60

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

480

70

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

560

90

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

720

100

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 

800

CHLORIDES Content up to 100 PPM level s are acceptable , in low pressure boiler , while more then 300 PPM level should be reduced by increased blowdown . Where as chlorides levels are very high the quality of the feed water should be checked in view to possible saline contamination.

Product video

Watch on video

Related products

Product FAQs

From our blog

Need Chloride Test Kit for your operation?

Our team helps with product selection, dosage, safety data and delivery worldwide.

Request a Quote