Corrosion Inhibitor for Diesel Cooling Water Treat

Deck cabin galley Maintenance-25

Corrosion Inhibitor for Diesel Cooling Water Treat

Water-soluble corrosion inhibitors FOR engine water treatment

Anti-Scalant for use in closed cooling water systems , for preventing corrosion and scale Formation in Internal combustion engines, compressor cooling system, DG -set at high or low temperature. It is a concentrated liquid , also used as a corrosion inhib

Key details

Generic name Water-soluble corrosion inhibitors FOR engine water treatment
IMPA code 551086,
Active matter (%) 45-50
Standard packing 25.00 Ltr.
Available pack sizes 5, 10, 20 / 25 / 35 / 50 / 210 Ltrs customized and private labeling option available for Water-soluble corrosion inhibitors FOR MTU engine. Mail us for MSDS and technical bulletin as well as for factory discounted sale price. Corrosion Inhibitor for Diesel Cooling Water Treatment, Ready stock at KANDLA, Mundra, Mumbai, Chennai, Vizag - Visakhapatnam, Kolkata - Haldia, Fujairah - Dubai, Middle East - UAE.
Supply locations Marine Chemicals Boiler water treatment chemicals Fuel oil treatment chemicals Tank cleaning chemicals Test kits and reagents Cooling water treatment chemicals Oil spill dispersant Electric cleaning chemicals Air cooler cleaning chemical Antiscalants Defoamers /Surfactants Oxygen Scavengers Custom Blending of Water Treatment Chemicals Water Treatment Chemicals - Raw Coagulants Flocculants Disinfectants Corrosion Inhibitors RXSOL WATER TREATMENT CHEMICALS : 1. Sodium Chloride salt for softeners 2. Calcium hypochlorite 65-70% 3. Ferric Chloride 40% 4. Sodium metabisulphite powder 5. Sodium Bromide. 6. Bromine Tablets suppliers in uae, Dubai, Sharjah. 7. Sodium Nitrite. 8. Sodium Molybdate 9. Phenolphthalein White 10. Caustic Soda liquid, Prills and flakes. 11.Ferrous Sulphate. 12.Poly Aluminium Chloride (PAC). 13.Calcium Nitrate. 14.Calcium Chloride. 15.Sodium Sulphite. 16.Silica Sand and Gravel filtration media. 17.Birm and Anthracite. 18.Hydrazine Hydrate. 19.Carbohydrazide liquid and powder. 20.Cobalt Sulphate. 21.Zinc Chloride and Zinc Sulphate 22.Borax Pentahydrate and Borax Decahydrate 23.Citric acid solution and powder. 24.Sodium Hexameta phosphate. Boiler Water Treatment Chemicals Precleaning & Passivation Scale Inhibitors Corrosion Inhibitors pH Booster (Inorganics & Organics) Descaling Chemicals (online / offline) Sludge Conditioner Condensate Treatment Chemicals Amine Based treatment Scale Inhibitors Corrosion Inhibitors Biocides Biodispersant Dealkalisers Descalants Cooling Water Treatment Chemicals Chiller Water Treatment Chemicals Pre cleaning Chemicals Anticorrosion Treatment Antimicrobial Treatment STP Treatment Chemicals Biocultures Deodorants Biomass Setting Agents Disinfectants Defoamers Nutrients Enzymes ETP Treatment Chemicals Coagulant Flocculant Decolorant Dewatering Aids / Filter Aids Bioculture – Anaerobic & Aerobic Deodorants De-Emulsifiers Polymers for Filter Press / dewatering Evaporator Antiscalants Water Treatment Chemicals Biocides Coagulants/flocculants Corrosion inhibitors Defoamers Dust control products Membrane treatments Metal passivators Monitoring and control systems Odor inhibitors Oxygen scavengers Scale inhibitors Sludge dewatering polymers MUNICIPAL water treatment chemicals Coagulants/flocculants Defoamers Feed / make down equipment Membrane treatments Mixing equipment Odor inhibitors Scale inhibitors Sludge dewatering polymers MINING & MINERAL PROCESSING Coagulants/flocculants Dust control products Filtration aids Grinding aids Monitoring and control systems Non-sulfide flotation reagents Rheology modifiers Scale inhibitors Specialty dewatering aids Viscosity modifiers CHEMICAL PROCESSING Biocides Cleaners Coagulants/flocculants Corrosion inhibitors Defoamers Membrane treatments Monitoring and control systems Odor neutralizer Oxygen scavengers RO Membrane Treatment Chemicals RO Pre -Treatment Chemicals Membrane Antiscalants Raw water RO (Food grade) Effluent Recycle RO Desalination Plants Membrane Antioxidants Membrane Cleaning Chemicals Membrane Preservatives Online / Offline Biocides pH Boosters (Food Grade) Taste Enhancers for RO Product water Sanitizing Products for PSF, ACF Filter Media and Pipelines. Sugar Process Chemicals Boiler Treatment Chemicals Juice Clarification Aids Syrup Clarification Aids Mill Sanitation Chemicals Viscosity Reducer Anti Foamer / Defoamer Evaporator Antiscalant & Descalants Sugar Refining Compounds Color Precipitants Paper Process Treatment Chemicals Anti Slimicides Defoamers Chemicals For Krofta Applications Boil –out Chemicals Vacuum Pump Antiscalant ETP Chemicals

Need this product at your port or plant?

Enquire Now
Application

The stable oxide film that is formed by RXSOL CIDC prevents corrosion caused by the electrolytic action between dissimilar metals used in the system .RXSOL CIDC has been field tested and found to have no detrimental effects on non-metallic substances such as seals, glands, packing, hoses, gaskets etc., normally used in these’ systems.

Application-Dg*

Sets Internal combustion engines closed circuit cooling system compressor cooling system. RXSOL CIDC incorporates superior corrosion inhibitors to prevent corrosion works by free of scale deposits.

Using Procedure

Initial dosage for an untreated system is 9 litres of RXSOL CIDC / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL CIDC every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval.

Technical Specifications

SPECIFICATION / HANDLING
Color                           : Odour Pink/ red (Colour changes of the product cannot be excluded the effects will however not impaired.)
Sp. Gravity                  : 1.1 to 1.25
pH                               : Alkaline (11.3 – 11.5)
None. Rxsol-2000 is an alkaline product & should be handled like other chemical Avoid contact with Eyes, Skin, in case of contact, wash with copious amounts of water immediately.
Freezing Point - 17 0 c

Nitrite (as PPM NO2)       0                   100-200      300-600        700-900      1100-1300      1440-2400
RXSOL CIDC /1000L      13.0               11.3              8-10               5-7               1.5-3.5              0

Remarks

METHOD OF USE
1. Properly clean the system with water and alkaline liquid, if necessary.
2. Add 0 .15-1.5 % of RXSOL CIDC in the system or recommended Nitrite level 1400 – 2500 ppm can be measured and controlled by any standard RXSOL test kit for Nitrite, Chloride test also helps to detect excess contamination to maintain acceptable levels. when the product is dosed as recommended limit By buffering action of RXSOL CIDC, pH should be maintained between 8.3 and 10 by the treatment.