Hardness Control Boiler Treatment
Boilere Water Treatment for Hardness Control
Phosphate Boiler Water Treatment Hardness Control is a white dry powder Phosphate Boiler Water Treatment product used for the reduction of hardness in boilers. Hardness Control is highly soluble in water and It will precipitate calcium hardness as a non-a
Key details
| Generic name | Boilere Water Treatment for Hardness Control |
|---|---|
| IMPA code | 551441 |
| Standard packing | 20.00 Kg.PWD |
| Available pack sizes | 25 |
| Supply locations | Hardness Control 20 Kgs manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Hardness Control 20 Kgs at a competitive price from us. We have ready stock of Hardness Control 20 Kgs in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders. |
Need this product at your port or plant?
Enquire Now<p style="text-align: justify;">
<span style="font-size:14px;"><span style="font-family: verdana, geneva, sans-serif;">Hardness Control is formulated to form a precipitate with calcium ions which will not adhere to metal surfaces but are in a form suitable for blowdown.</span><br />
<br />
Used for boilers and water softening.</span></p>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">For optimum results dose Hardness Control direct to the boiler via the bypass pot-feeder. The dry powder should be dissolved in hot water (50°C) at a ratio of 1 part powder to twenty parts condensate (e.g. 500 grams/10 litres). Ensure that treatment is fully dissolved before dosing.</span></p>
<p style="text-align: justify;">
<span style="font-size:14px;"><strong><span style="font-family: verdana, geneva, sans-serif;">Sampling And Testing</span></strong><br />
<br />
<span style="font-family: verdana, geneva, sans-serif;">A sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Rxsol Hardness Test Kit instructions and fill the Boiler Water Log Form according to result results. It is important that regular testing is carried out to ensure levels of treatment are correct.</span></span></p>
<p style="text-align: justify;">
<span style="font-size:14px;"><strong><span style="font-family: verdana, geneva, sans-serif;">Physical Properties :</span></strong></span></p>
<p style="text-align: justify;">
<span style="font-size:14px;"><span style="font-family: verdana, geneva, sans-serif;">Appearance :White powder<br />
Corrosive action : non<br />
pH 1% solution : 8,8<br />
Flash point : none</span></span></p>
<p style="text-align: justify;">
<span style="font-size:14px;"><span style="text-align: justify;">A precipitant designed to elimate scale deposits and lower the hardness of water in boilers with working pressure up to 60 bars.</span><br style="text-align: justify;" />
<br style="text-align: justify;" />
<span style="text-align: justify;">It is used in conjunction with alkaline liquid to prevent calcium scale deposits. Both products are used in our standard boiler water treatment programs for low-pressure boiler systems (0-32 bar) and medium-pressure steam propulsion vessels (32-60 bar).</span></span></p>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">This treatment dosed at 1.49 grams per ton of distilled water provides 1.0 ppm phosphate.<br />
Feed Points: Dose with other BOILER CHEMICAL / alkaline liquid by diluting withcondensate and feed directly into the system drum (below the water level) using a bypass pot feeder. For low-pressure boilers, It may be dosed to the hotwell or condensate return tank, although this is not the preferred method.</span><br />
</p>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"><strong>Dosage and control</strong></span></p>
<table border="1" cellpadding="0" style="width: 935px;" width="100%">
<tbody>
<tr>
<td style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> </span></td>
<td colspan="6">
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">Phophate test result in pPM PO4</span></p>
</td>
<td style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> </span></td>
</tr>
<tr>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> Pressure</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> 0 - 10</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">10 - 20</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">20 - 30</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">30 - 40</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">40 - 50</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">> 50</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> <strong>Control range</strong></span></p>
</td>
</tr>
<tr>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> 0-40 Bar<br />
0-588 PSI</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> 23</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">11.5 </span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">Satisfactory</span></p>
</td>
<td colspan="2">
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">Satisfactory</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">Blow Down</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> <strong>20-50</strong></span></p>
</td>
</tr>
<tr>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">41-60 Bar<br />
589-880 PSI </span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> 17</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> 5.5</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">Satisfactory</span></p>
</td>
<td colspan="2">
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">Blow Down</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">Blow Down</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> <strong>15-30</strong></span></p>
</td>
</tr>
<tr>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> > 60 Bar<br />
> 880 PSI</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> 5.5</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"> Satisfactory</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">Satisfactory</span></p>
</td>
<td colspan="2">
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">Blow Down</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">Blow Down</span></p>
</td>
<td>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;"><strong> 10-25</strong></span></p>
</td>
</tr>
</tbody>
</table>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">Select row on righthand side for applicable pressure range. Compare test result with comment in table and dose stated amount of product per ton boiler water volume.</span></p>
<p style="text-align: justify;">
<span style="font-family: verdana, geneva, sans-serif;">These are recommended values based on experience and are in no way intended to replace the boiler manufacturer's specifications or company regulations.</span></p>
From our blog
Need Hardness Control Boiler Treatment for your operation?
Our team helps with product selection, dosage, safety data and delivery worldwide.
Request a Quote