Clog Controller Biocide

Evaporator Treat-51

Clog Controller Biocide

Part No. RXSOL-40-4009-050

Microbiocide for cooling water Bacteria and Algae Control.

Strong algae depressant fully compatible with alkalizing and flocculating agents normally used in cooling / boiler water. Algae growth is the main cause of colour in water. Routine and weekly additions of RXSOL-40-4009-050 establish a buffer action to control very rapid algae growth.

Key details

Part number RXSOL-40-4009-050
Generic name Microbiocide for cooling water Bacteria and Algae Control.
Standard packing 50.00 Ltr.
Available pack sizes 5, 10, 20, 25, 50, 210 Ltr Microbiocide for cooling water Bacteria and Algae Control.
Supply locations BIOCIDE MICRO Cooling Water 20 Ltr manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of BIOCIDE MICRO Cooling Water 20 Ltr at a competitive price from us. We have ready stock of BIOCIDE MICRO Cooling Water 20 Ltr in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Need this product at your port or plant?

Enquire Now
Application

<p>
Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system.</p>
<p style="text-align: justify;">
<span style="font-size: 14px;">Clog Controller Biocide RXSOL-40-4009-050</span><span style="font-size: 14px;"> is a high performance non-oxidising micro-biocide that uses the latest chemical technologies for the rapid and effective treatment of cooling water systems. RXSOL-40-4009-050 is a rapid acting micro-biocide developed for use in cooling water systems and is effective against Legionella bacteria, SRB’s, algi and fungi. RXSOL-40-4009-050 will also penetrate and disperse biofilm slimes making it an ideal cooling water treatment. RXSOL-40-4009-050  has an excellent environmental profile and is readily biodegradable.</span></p>

Using Procedure

<p style="text-align: justify;">
<span style="text-align: justify; font-size: 14px;">Clog Controller Biocide RXSOL-40-4009-050</span><span style="text-align: justify; font-size: 14px;">  is an </span><span style="text-align: justify; font-size: 16px;">organic chlorine releasing microbiocide which will effectively control the growth of algal slimes on cooling Water distribution decks, fill, and basins.</span><br style="text-align: justify; font-size: 14px;" />
<span style="text-align: justify; font-size: 14px;">This product is recommended for use in industrial process cooling towers, air conditioning cooling systems, and evaporative condensers. It is particularly recommended for use in systems where </span><span style="text-align: justify; font-size: 16px;">algae growth is especially difficult to control.</span></p>

Remarks

<p style="text-align: justify;">
<span style="font-size: 14px;">Clog Controller Biocide RXSOL-40-4009-050</span><span style="font-size: 14px;"> should be dosed periodically at a rate of 75 - 150 ppm of the total system volume. In a badly fouled system an initial dosage rate of up to 250m1/m3 may be required which can be reduced once control is gained.In order to comply with Health & Safety recommendations </span><span style="font-size: 14px;">Clog Controller Biocide RXSOL-40-4009-050</span><span style="font-size: 14px;"> should be alternated with another non-oxidising or oxidizing biocide. It is always advisable to carry out a 'Control Of Substances Hazardous to Health' (COSHH) assessment before use.</span></p>

Note

<div id="cke_pastebin" style="text-align: justify;">
<span style="font-size: 14px;">Where </span>MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 can be used?<br />
<br />
<span style="font-size: 14px;">For the control of microbial biofilms, bacteria, algae, and fungi, add </span><strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-050</strong><span style="font-size: 14px;"> to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling </span><span style="font-size: 14px;">systems, brewery pasteurizer and can warmer systems. Add </span><strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-050</strong><span style="font-size: 14px;"> at some point in the system to ensure uniform mixing.<br />
<br />
<span style="font-size: 16px;">Dose Ratio</span> of </span><strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-050 </strong><br />
<span style="font-size: 14px;">NOTE: </span>Badly fouled systems should be cleaned before treatment.<br />
<div>
 </div>
<div id="cke_pastebin">
INITIAL DOSE: if the system is initiating fouling then use 200 ml - 3 ltr of  <strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-050  for </strong>per 3000 to 5000 Ltr of water in the system.) Dose can be increased till optimum results.</div>
<div>
 </div>
<div id="cke_pastebin">
WEEKLY CONTROL DOSE: When microbial control is evident, add 100 to 500 ml per <strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-050  for </strong>per 3000 to 5000 Ltr of water in the system</div>
<div id="cke_pastebin">
 </div>
<div id="cke_pastebin">
AIR WASHER SYSTEMS : Add to the air washer sump or chill water sump to insure uniform mixing, 200 ml  - 3 Ltr of <strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-050  for </strong>per 3000 to 5000 Ltr of water in the system, DOSE ration directly proportional of  contamination to control microbial biofilms, bacteria, fungi, and algae which cause fouling in industrial air washer systems.</div>
<div>
 </div>
<div>
<div id="cke_pastebin">
<br />
<br />
<div id="cke_pastebin">
<span style="font-size: 14px;"><span style="font-size: 16px;">Dose Ratio</span> </span><span style="font-size: 14px;">of </span><strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-050 </strong><span style="font-size: 14px;">for </span>CONTINUOUS FEED METHOD <strong> </strong></div>
<div id="cke_pastebin">
<br />
Maintain this treatment level by adding a continuous feed of 100 ml to 1000 ml of <strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-050 </strong> per 1000 gallon of makeup water).<br />
<br />
NOTE : Badly fouled systems must be cleaned before initial treatment.</div>
<div>
 </div>
<div>
 </div>
</div>
</div>
</div>
<div id="cke_pastebin">
<div>
 </div>
<div id="cke_pastebin">
<span style="text-align: justify; font-size: 16px;">Dose Ratio</span><span style="font-size: 14px; text-align: justify;"> </span><span style="text-align: justify; font-size: 14px;">of </span><strong style="text-align: justify;">MICRO BIOCIDE Cooling Water RXSOL-40-4009-050 </strong><span style="font-size: 14px; text-align: justify;">for </span>INDUSTRIAL WASTEWATER TREATMENT SYSTEMS AND SEWAGE SYSTEMS</div>
<div id="cke_pastebin" style="text-align: justify;">
<br />
INITIAL DOSE for Noticeably Fouled Condition: 500 ml - 4000 ml of <strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-050 </strong> per 3000 Ltr of water in the system. Repeat until control is achieved. Badly fouled systems should be cleaned before treatment is begun.</div>
<div id="cke_pastebin">
<br />
SUBSEQUENT DOSE: When microbial control is evident, add 100 ml  - 100 ml <strong style="text-align: justify;">MICRO BIOCIDE Cooling Water RXSOL-40-4009-050 </strong><span style="text-align: justify;"> per 3000 Ltr of water in the system.</span></div>
</div>

Need Clog Controller Biocide for your operation?

Our team helps with product selection, dosage, safety data and delivery worldwide.

Request a Quote