Corrosion Inhibitor Closed Open Cooling Water System

Corrosion Inhibitor Corrosion Inhibitor Closed Open Cooling Water System
Express Port Supply: 2-4 Hr Berth Delivery Across Major Indian & UAE Ports
ISO 9001:2015 Certified QA
IMPA / ISSA Marine Standard
Ready Stock 25L, 210L, IBC
Corrosion Inhibitor

Corrosion Inhibitor Closed Open Cooling Water System

Part No. RXSOL-40-4028-025

Chilling UNIT corrosion Inhibitor

RXSOL-40-4028 creates an insoluble polymeric surface complex on copper and its alloys also works synergistically with other inhibitors to effectively control the corrosion of steel and aluminium in the system.

Key Technical Details
Part number RXSOL-40-4028-025
Generic name Chilling UNIT corrosion Inhibitor
Active matter (%) 72-81
Standard packing 25.00
Available pack sizes Chilling UNIT corrosion Inhibitor available in 25, 50 Ltr and also in 210 Ltr Drum
Supply locations Corroision Inhibitor for closed & Open cooling system manufacturer and supplier in Fujairah, Dubai, Sharjah, Ajman, Sharajah, UAE MIddel East, Muscat, Barka, Sohar Oman, Mumbai, Kolkata, Vizag, Chennai, Gandhidham, Surat Gujrat, Nairobi Kenya, Canada
Application

In particular, RXSOL-40-4028 creates an insoluble polymeric surface complex on copper and its alloys, and also reacts with copper in solution. RXSOL-40-4028 also works synergistically with other inhibitors to effectively control the corrosion of steel and aluminium in the system.

Control and dosage of RXSOL-40-4028 - The dosage of RXSOL-40-4028 required varies widely with different applications.

Using Procedure

Recommended Dosing

These values refer to active triazole concentration in circulating water, not the amount of commercial product.

Application

Indicative Active Triazole Target

Open cooling tower – initial treatment

10–20 ppm

Open cooling tower – maintenance

1–3 ppm

Closed cooling water system

2–10 ppm, according to metallurgy and program

Aggressive water conditions

Determine from corrosion testing

Typical open-tower passivation and maintenance ranges are supported by published cooling-water treatment guidance. Closed-loop requirements can vary significantly, particularly with mixed metallurgy.

For a product containing 19.8% active triazole, a theoretical 5 ppm active treatment in 100,000 litres requires approximately 2.53 kg of product, excluding consumption and system losses.

Typical initial dosage for an untreated system is 8 liters of product per 1000 liters of water.

Technical Specifications

Technical Specifications

Parameter

Characteristics

Appearance

Clear to Pale amber liquid

Base Content

Triazole

pH at 25°C

Alkaline; establish validated range

Specific Gravity

>1

Water Compatibility

Dilutable in treatment water

Foam Formation

Low, subject to testing

Shelf Life

Establish through stability testing

Remarks

Key Advantages

  • Excellent corrosion inhibition for copper and copper alloys.

  • Helps minimize copper corrosion and metal-ion release.

  • Suitable for open and closed cooling water systems.

  • Compatible with many phosphate, phosphonate, molybdate and polymer-based treatment programs, subject to testing.

  • Helps protect copper tubes in condensers and heat exchangers.

  • Available as a concentrated liquid formulation.

  • Can be formulated as a nitrite-free product.

  • Suitable for integration into multi-metal corrosion inhibitor programs.

Important: Triazoles primarily protect copper and copper alloys. For carbon steel, cast iron and aluminium, additional corrosion inhibitors are generally necessary.

Note

Product Description

RXSOL Triazole-Based Corrosion Inhibitor is a specialized corrosion-control treatment designed to protect copper, brass, bronze and copper-alloy components in industrial cooling water systems.

The product utilizes triazole chemistry to form a protective film on copper-containing surfaces, minimizing metal dissolution, corrosion and copper-ion release.

It can be incorporated into both open recirculating and closed-loop cooling water treatment programs.


RXSOL-40-4028-025 is water treatment chemicals and cleassified as a cooling water treatment chemicals. RXSOL-40-4028-025 principally works as corrosion inhibitors in cooling water treatment chemicals.

RXSOL-40-4028-025 most commonly used as a corrosion inhibitor for open closed cooling water systems.

Need Corrosion Inhibitor Closed Open Cooling Water System for your operation?

Our team helps with product selection, dosage, safety data and delivery worldwide.

Request a Quote