pH Booster Morpholine Base

RO Chemicals-33

pH Booster Morpholine Base

Part No. RXSOL-33-5024-250

Alkaline and Hardness Controller

RXSOL pH Boosters are morpholine based alkaline formulation,used as alkalinity source for boiler feed water. It is synergized with properties of pH boosting and water conditioning.

Key details

Part number RXSOL-33-5024-250
Generic name Alkaline and Hardness Controller
Active matter (%) 60 - 63
Standard packing 250.00 Kg.Liq
Available pack sizes 25 Kgs. 50 Kgs.
Supply locations pH Booster Morpholine Base manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of pH Booster Morpholine Base at a competitive price from us. We have ready stock of pH Booster Morpholine Base in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Need this product at your port or plant?

Enquire Now
Application

<p style="text-align: justify;">
RXSOL-40-5024-020 have<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;"> <em><span style="font-size:16px;">antiscalant property</span></em>  which will help to formation of scale inside the boiler. This makes it profitable for users by savings of power and labor, and increase in production.  As Uses of antiscalants is a prime necessity to meet up with production targets.</span><br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">pH booster is an alkaline liquid formulation designed to increase alkalinity of  feed water  of boiler. It is also used to reduce corrosion of feed water tank,lines & pump.  </span><br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;"><span style="background-color:#f0fff0;">CORROSION REDUCTION</span></span><br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">pH booster Increases ph of the feed water reducing corrosiveness.it also increases alkalinity in boiler water reducing scaling & corrosion of the boiler metal.</span><br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;"><span style="background-color:#f0fff0;">EASY SLUDGE REMOVAL</span></span><br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">pH booster is helps in formation of non adherent sludge.it fluidises the sludge which is then removed easily during normal blow-down. non- toxic and non-corrosive liquid formulation and therefore can be handled  easily.</span></p>

Using Procedure

<p style="text-align: justify;">
RXSOL  pH Boosters are dosed depending upon the feed water characteristic and alkalinity requirement. It is compatible with all other treatment chemicals. It is dosed exactly as per the dosage rate and method of RXSOL-50-5001-025</p>
<p>
 </p>
<p style="text-align: justify;">
<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">EASY TO HANDLE</span><br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">pH booster is non- toxic liquid formulation and therefore can be handled  easily. </span><span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">pH booster should be dosed continuously. Dose the dilute solution  in boiler feed  water line.  </span></p>

Technical Specifications

<p>
 </p>
<table border="1" cellpadding="1" cellspacing="1" style="width: 329px; height: 163px">
<tbody>
<tr>
<td>
<strong>Properties</strong></td>
<td>
<strong>Unit</strong></td>
<td>
<strong>Typical Value</strong></td>
</tr>
<tr>
<td>
Form and Appearance</td>
<td>
-</td>
<td>
Clear Colorless Liquid</td>
</tr>
<tr>
<td>
Odor</td>
<td>
-</td>
<td>
Characteristic</td>
</tr>
<tr>
<td>
pH (neat)</td>
<td>
pH</td>
<td>
Alkaline</td>
</tr>
<tr>
<td>
Solubility</td>
<td>
-</td>
<td>
Completely Soluble in Water</td>
</tr>
</tbody>
</table>

Remarks

<p>
<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">STORAGE & HANDLING</span><br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">pH booster should be stored in an air tight container away from direct heat.<br />
Always store at cool & dry place.<br />
Handle using goggles & do not breathe in the vapours.<br />
Wash thoroughly in case of contact. Do not swallow.</span><br />
 </p>
<p style="text-align: justify;">
pH Control</p>
<p style="text-align: justify;">
Maintenance of proper pH throughout the boiler feedwater, boiler, and condensate systems is essential for corrosion control. Most low-pressure boiler system operators monitor boiler water alkalinity because it correlates very closely with pH, while most feedwater, condensate, and high-pressure boiler water requires direct monitoring of pH. Control of pH is important for the following reasons:</p>
<ul>
<li style="text-align: justify;">
corrosion rates of metals used in boiler systems are sensitive to variations in pH</li>
<li style="text-align: justify;">
low pH or insufficient alkalinity can result in corrosive acidic attack</li>
<li style="text-align: justify;">
high pH or excess alkalinity can result in caustic gouging/cracking and foaming, with resultant carryover</li>
<li style="text-align: justify;">
speed of oxygen scavenging reactions is highly dependent on pH levels</li>
</ul>
<p style="text-align: justify;">
The pH or alkalinity level maintained in a boiler system depends on many factors, such as sys-tem pressure, system metals, feedwater quality, and type of chemical treatment applied.</p>
<p style="text-align: justify;">
The corrosion rate of carbon steel at feedwater temperatures approaches a minimum value in the pH range of 9.2-9.6 . It is important to monitor the feedwater system for corrosion by means of iron and copper testing. For systems with sodium zeolite or hot lime softened makeup, pH adjustment may not be necessary. In systems that use deionized water makeup, small amounts of caustic soda or neutralizing amines, such as morpholine and cyclohexylamine, can be used.</p>
<p style="text-align: justify;">
In the boiler, either high or low pH increases the corrosion rates of mild steelThe pH or alkalinity that is maintained depends on the pressure, makeup water characteristics, chemical treatment, and other factors specific to the system.</p>
<p style="text-align: justify;">
The best pH for protection of copper alloys is somewhat lower than the optimum level for carbon steel. For systems that contain both metals, the condensate and feedwater pH is often maintained between 8.8 and 9.2 for corrosion protection of both metals. The optimum pH varies from system to system and depends on many factors, including the alloy used </p>
<p style="text-align: justify;">
To elevate pH, neutralizing amines should be used instead of ammonia, which (especially in the presence of oxygen) accelerates copper alloy corrosion rates. Also, amines form protective films on copper oxide surfaces that inhibit corrosion.</p>

Note

<p>
<strong>Key Features & Benefits:-</strong></p>
<p>
Minimizes corrosion of feed water tank, lines and pump</p>
<p>
Imparts water and sludge conditioning to minimize scaling and deposition</p>
<p>
Compatible with other treatment Chmicals</p>
<p>
Completely biodegradable chemicals<br />
<span style="font-family: arial, sans-serif; font-size: small; text-align: justify;">Its antiscale property helps and Prevent from Scaling</span></p>
<p>
<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">Minimum downtime required for descaling</span><br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">Multipurpose,therefore easy to use</span><br style="text-align: justify; font-family: arial, sans-serif; font-size: small;" />
<span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">Proper maintenance of boiler saves Power / Fuel saving upto 70%. Formation of Scale is major issue and contol of scale makes </span><span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">Effectively heat transfer which </span><span style="text-align: justify; font-family: arial, sans-serif; font-size: small;">Increase productivity.</span></p>

Need pH Booster Morpholine Base for your operation?

Our team helps with product selection, dosage, safety data and delivery worldwide.

Request a Quote