ROKOR NB Corrosion Inhibitor

Cooling Water Chemical-43

ROKOR NB Corrosion Inhibitor

Part No. RXSOL-43-4001-050

Ferrous Oxide Cleaner for Cooling Water Treatment

Iron Oxide Cleaner blended with corrosion Inhibitor for Water Systems having unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants , dispersant and buffer solution of non carbonate.Usefull for use in hig

Key details

Part number RXSOL-43-4001-050
Generic name Ferrous Oxide Cleaner for Cooling Water Treatment
IMPA code 551036 , 551037
Active matter (%) 68-75%
Standard packing 25.00 Kg.Liq
Available pack sizes Iron Oxide Cleaner available in 5, 20, 25, 50 and 210 Ltrs drum. Most popular engine water treatment chemicals to protect the metallic surface from corrosion.
Supply locations Iron Oxide Cleaner manufacturer, exporter and supplier in Mumbai, Navi Mumbai MIDC, Chennai, Ennore, Kolkata, Visakhapatnam, Haldia, Paradip, Visakhapatnam, Fujairah, Dubai, Abudhabi, Ajman, Barka, Muscat, Oman, Nairobi Mombasa Kenya Africa, Canada

Need this product at your port or plant?

Enquire Now
Application

<p style="text-align: justify">
Prolongs the life of equipment by keeping it scale and corrosion free. Since Iron Oxide Cleaner is alkaline, it will<span style="font-size: 16px"><em> suppress acid corrosion</em></span>, which would otherwise result in sever pittings. It improves cooling efficiency by maintaining clean heat transfer surfaces , from Radiators, DG - sets, Closed Cooling and chiller System.<br />
<br />
<span style="font-size:16px;"><em>( Used as a corrosion inhibitor for all ferrous and non-ferrous metals found in water systems ) </em></span><br />
 </p>

Using Procedure

<p>
Refer to technical datasheet.</p>
<p style="text-align: justify">
<strong>GENERAL RECOMMENDATION</strong> : </p>
<table border="0" cellpadding="1" cellspacing="1" style="width: 517px; height: 113px">
<tbody>
<tr>
<td style="width: 25%">
Nitrite (as PPM NO2)</td>
<td style="width: 15%">
<span style="background-color: #00ff00">0  </span></td>
<td style="width: 15%">
<span style="background-color: #ffff00">100-200</span></td>
<td style="width: 15%">
<span style="background-color: #ffff00">300-600</span></td>
<td style="width: 15%">
<span style="background-color: #ffff00">700-900</span></td>
<td style="width: 15%">
<span style="background-color: #f00">1100-1300   </span></td>
</tr>
<tr>
<td>
RXSOL-43-4001-050 / 1000L</td>
<td>
<span style="background-color: #00ff00">13.0  </span></td>
<td>
<span style="background-color: #ffff00">11.3</span></td>
<td>
<span style="background-color: #ffff00">8-10 </span></td>
<td>
<span style="background-color: #ffff00">5-7   </span></td>
<td>
<span style="background-color: #f00">1.5-3.5 </span></td>
</tr>
</tbody>
</table>
<p>
NOTE ::: --  <em><span style="font-size: 14px"> If nitrite level becomes 1440-2400 then doses should be ZERO</span></em>.</p>

Remarks

<p style="text-align: justify;">
<span style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;">Before testing of Nitrite level, Here is some point and guideline,  what you need to do. : <strong>1</strong> take the following readings; pH, TDS </span><span style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;">(uS), and nitrite level.and record. <strong>2</strong> add the Chemical your are using. </span><span style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;"><strong>3</strong>. wait for a period of time for the sysem to circulate. <minimum 3 -4 </span><span style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;">hours> <strong>4</strong>. Re check the readings. and record. 5 track these readings</span><br style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;" />
<span style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;">for a period of time.</span><br style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;" />
<br style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;" />
<span style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;">If the TDS and Nitrite drop you have a leak/ unknown makeup. if the </span><span style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;">TDS stays stable and the nitrite drops you have a biological problem. </span><span style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;">Bacteria that convert nitrite to nitrate.</span><br style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;" />
<br style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;" />
<span style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;">Solution ::: Use DI water in place of general water, And also use. </span><span style="text-align: justify; font-family: arial, sans-serif; font-size: 12.8px;">Algaecide to control Bacterial growth inside water system ... </span><a data-saferedirecturl="https://www.google.com/url?hl=en&q=http://rxmarine.com/Biocide-Algaecid…; href="http://rxmarine.com/Biocide-Algaecide&quot; rel="noreferrer" style="text-align: justify; color: rgb(17, 85, 204); font-family: arial, sans-serif; font-size: 12.8px;" target="_blank">http://rxmarine.com/Biocide-<wbr>Algaecide</wbr></a></p&gt;

Note

<p style="text-align: justify">
Initial dosage for an untreated system is 9 litres of Iron Oxide Cleaner / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL-40-4001-020 Iron Oxide Cleaner every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval. Specially designed for use in  water systems of internal combustion equipment. pH should be maintained between 8.3 and 10 by the treatment.</p>

Need ROKOR NB Corrosion Inhibitor for your operation?

Our team helps with product selection, dosage, safety data and delivery worldwide.

Request a Quote