MICRO BIOCIDE Cooling Water
MICROORGANISM CONTROLER
Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system. being effective against most kinds of bacteriaa, algae and fungi. It is a particularly useful product for air-wash systems and is compatible with all commonly used antifoulants and corrosion inhibitors.
Key details
| Generic name | MICROORGANISM CONTROLER |
|---|---|
| Standard packing | 25.00 Ltr. |
| Available pack sizes | MICRO BIOCIDE Cooling Water used For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems. available in 5 Ltr, 25, 50, 210 Ltr PACK. |
| Supply locations | MICRO BIOCIDE Cooling Water manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai Abudhabi, Sharjah UAE, Muscat Oman, Kenya Africa. Get the best quality of MICRO BIOCIDE Cooling Water at a competitive price from us. We have ready stock of MICRO BIOCIDE Cooling Water in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders. |
Need this product at your port or plant?
Enquire NowMicrobiocide based on Organo sulphur compound, for use in open recircurculating systems.
* Highly effective
* Broad spectrum activity
* Economical and easy to use
* Compatible with other treatments.
Routine dosage of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 IS 50 to 100ppm. based on the total water capacity of the system. Dosage will be necessary once or twice per week depending on the severity of the problem.
For badly fouled systems, initial higher dosage of 100-150 ppm. should be given for the first week or two.
The calculate quantity of biocide should be added directly to the system at any convienient point.
<div id="cke_pastebin" style="text-align: justify;">
<span style="font-size:14px;">Where </span>MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 can be used?<br />
<br />
<span style="font-size:14px;">For the control of microbial biofilms, bacteria, algae, and fungi, add </span><strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-025</strong><span style="font-size:14px;"> to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling </span><span style="font-size: 14px;">systems, brewery pasteurizer and can warmer systems. Add </span><strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-025</strong><span style="font-size: 14px;"> at some point in the system to ensure uniform mixing.<br />
<br />
<span style="font-size:16px;">Dose Ratio</span> of </span><strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 </strong><br />
<span style="font-size: 14px;">NOTE: </span>Badly fouled systems should be cleaned before treatment.<br />
<div>
</div>
<div id="cke_pastebin">
INITIAL DOSE: if the system is initiating fouling then use 200 ml - 3 ltr of <strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 for </strong>per 3000 to 5000 Ltr of water in the system.) Dose can be increased till optimum results.</div>
<div>
</div>
<div id="cke_pastebin">
WEEKLY CONTROL DOSE: When microbial control is evident, add 100 to 500 ml per <strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 for </strong>per 3000 to 5000 Ltr of water in the system</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
AIR WASHER SYSTEMS : Add to the air washer sump or chill water sump to insure uniform mixing, 200 ml - 3 Ltr of <strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 for </strong>per 3000 to 5000 Ltr of water in the system, DOSE ration directly proportional of contamination to control microbial biofilms, bacteria, fungi, and algae which cause fouling in industrial air washer systems.</div>
<div>
</div>
<div>
<div id="cke_pastebin">
<br />
<br />
<div id="cke_pastebin">
<span style="font-size: 14px;"><span style="font-size: 16px;">Dose Ratio</span> </span><span style="font-size: 14px;">of </span><strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 </strong><span style="font-size: 14px;">for </span>CONTINUOUS FEED METHOD <strong> </strong></div>
<div id="cke_pastebin">
<br />
Maintain this treatment level by adding a continuous feed of 100 ml to 1000 ml of <strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 </strong> per 1000 gallon of makeup water).<br />
<br />
NOTE : Badly fouled systems must be cleaned before initial treatment.</div>
<div>
</div>
<div>
</div>
</div>
</div>
</div>
<div id="cke_pastebin">
<div>
</div>
<div id="cke_pastebin">
<span style="text-align: justify; font-size: 16px;">Dose Ratio</span><span style="font-size: 14px; text-align: justify;"> </span><span style="text-align: justify; font-size: 14px;">of </span><strong style="text-align: justify;">MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 </strong><span style="font-size: 14px; text-align: justify;">for </span>INDUSTRIAL WASTEWATER TREATMENT SYSTEMS AND SEWAGE SYSTEMS</div>
<div id="cke_pastebin" style="text-align: justify;">
<br />
INITIAL DOSE for Noticeably Fouled Condition: 500 ml - 4000 ml of <strong style="text-align: justify;">MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 </strong> per 3000 Ltr of water in the system. Repeat until control is achieved. Badly fouled systems should be cleaned before treatment is begun.</div>
<div id="cke_pastebin">
<br />
SUBSEQUENT DOSE: When microbial control is evident, add 100 ml - 100 ml <strong style="text-align: justify;">MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 </strong><span style="text-align: justify;"> per 3000 Ltr of water in the system.</span></div>
</div>
<div id="cke_pastebin" style="text-align: justify;">
For the control of microbial biofilms, bacteria, algae, and fungi, add <strong style="text-align: justify;">MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 </strong>in recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems. Add <strong>MICRO BIOCIDE Cooling Water RXSOL-40-4009-025</strong> at some point in the system to insure uniform mixing.</div>
Growth of Legionella bacteria, SRB’s, algi and fungi etc can be control in COOLING TOWER, by RXSOL-40-4009-025 ?
Related products
Product FAQs
Need MICRO BIOCIDE Cooling Water for your operation?
Our team helps with product selection, dosage, safety data and delivery worldwide.
Request a Quote